LT-AC vs LT-PS vs LT-WG: Acoustic and Fluted Panel Parameter Guide

Three wall panel models are frequently quoted against the same interior drawing: LT-AC, a 21 mm acoustic slat panel; LT-PS, a 10 mm fluted PS panel; and LT-WG, a 12 mm WPC fluted panel with an 8 mm groove depth. They are not interchangeable. Module size, thickness, core construction, fire documentation and moisture behaviour determine which panel can be fixed to a given substrate, accepted by a given project specification, and expected to perform in the room where it is installed.
LONGTE — Haining Longtime Industry Co., Ltd. — is a wall panel and flooring manufacturer based in Haining, Zhejiang Province, China, founded in 2003, operating 80,000 m² of factory space with 220 employees and an export ratio of 85% across markets including the United States, UAE, India, the Philippines, Colombia and South America. Its panel portfolio includes acoustic slat panels, PS fluted panels and WPC fluted panels, which is why the three models are often shortlisted together for the same feature wall package.
This guide compares them strictly on measurable parameters, then converts those parameters into a selection sequence a specifier can run before issuing a purchase order.
Problem Definition: Why These Three Panels Get Specified Against the Same Drawing
Fluted and slat panels all read as 'linear feature panels' on a mood board, so they reach the same tender package. The parameter differences that follow are the ones that cause site problems.
- Assembly weight and substrate load. LT-AC is a 21 mm assembly of MDF slats mounted on polyester acoustic felt. LT-PS is a 10 mm PS profile and LT-WG is a 12 mm WPC profile. A 21 mm felt-backed slat panel and a 10 mm fluted profile do not share the same fixing design, batten spacing or wall build-up, and the heavier assembly must be checked against the substrate before it is drawn.
- Fire documentation scope. A fire classification applies to the product scope that was tested. Copying a report number from one panel onto a different SKU is one of the most common compliance failures in interior fit-out.
- Groove geometry misread. Five flutes across a 150 mm face (LT-PS) and an 8 mm groove depth on a 159 mm face (LT-WG) produce different shadow lines, different corner treatment and different cleaning behaviour in dusty or high-touch areas.
- Moisture exposure. An MDF-slat acoustic assembly is not the correct choice for a shower zone or a humid ceiling void. LT-WG is specified as waterproof; LT-AC is not.
- Module arithmetic. A 600 mm module, a 150 mm module and a 159 mm module generate very different cut waste at openings, corners and ceiling perimeters — a cost difference that appears only after the layout is drawn.
The practical consequence: the panel should be selected from the constraint set (fire, moisture, substrate, module) first, and from the visual reference second.
Industry Background: What Drives Panel Specification in 2026
The decorative wall panels market was valued at USD 30.70 billion in 2025, according to published industry research covering the sector to 2031. Within that total, metal wall panels held a 28.5% share by material in 2025, which leaves the majority of demand in non-metal categories such as PVC, WPC, wood-based and composite panels — the segment where LT-PS and LT-WG compete.
Two specification pressures dominate commercial interiors. The first is fire classification: B1-grade documentation is routinely requested for corridors, lobbies and hotel guest floors, and the acceptance decision usually rests on whether the report scope matches the SKU and colour actually supplied. The second is moisture and cleaning regime: panels specified for bathroom-adjacent walls, food service areas and high-traffic circulation zones are judged on whether they tolerate wet wiping without swelling or surface degradation.
Capacity matters to specifiers as well, because a compliant panel that cannot be delivered on programme is not a usable specification. LONGTE's monthly production capacity includes 800,000 m² of PVC panel and 80,000 m² of acoustic panel, alongside SPC flooring, WPC decking and PU stone lines — a useful reference point when a project requires a mixed container rather than a single SKU.
Detailed Solution: The Three Panels, Parameter by Parameter

LT-AC — Acoustic Slat Wood Wall Panel, 600 × 2400 mm, 21 mm
Model: LT-AC (Acoustic Slat Wood Wall Panel, customizable)
Panel size: 600 × 2400 mm
Thickness: 21 mm
Construction: MDF slats mounted on polyester acoustic felt
Compliance on file: CE Attestation of Conformity TD15322304, issued 2023-12-18 by EUTEST Belgelendirme (Turkey), valid to 2028-12-17, under EN 13950:2014 and EN 14496:2005, scope Acoustic Panel
LT-AC is a slat-and-felt assembly: the visible MDF slats provide the linear face, and the polyester felt behind them forms the backing layer that allows the panel to function as an acoustic element rather than a purely decorative one. The 600 mm width and 2400 mm length create a wide module, so fewer vertical joints are needed on a large feature wall, and the 21 mm total thickness gives the panel visible depth against the wall plane.
The felt layer is also the reason this panel carries a clear limitation. Absorption performance depends on cavity depth, felt density, slat spacing, installation pattern and room geometry. No absorption coefficient, NRC value or decibel reduction figure should be inferred from a product photograph or a generic data sheet — it should be confirmed by a project-specific test report. What can be stated from the documentation is the CE scope: TD15322304 covers Acoustic Panel under EN 13950:2014 and EN 14496:2005.
LT-PS — PS Polystyrene Fluted Wall Panel, 150 × 2900 mm, 10 mm

Model: LT-PS (PS Polystyrene Fluted Wall Panel, customizable)
Panel size: 150 × 2900 mm
Thickness: 10 mm
Construction: PS core with UV surface film, 5 flutes
Compliance on file: RoHS Verification of Conformity HN202410860, issued 2024-12-05 by Ningbo Helmsman Quality Testing Services Co., Ltd (HQTS), valid to 2029-12-04, under Directive 2011/65/EU and its amendment (EU) 2015/863, scope includes fluted wall panel
LT-PS is a slim decorative fluted profile: 150 mm wide, 2900 mm long, 10 mm thick, with five flutes across the face and a UV surface film forming the visible finish. The narrow module and long length make it a detailing panel rather than a broad-plane panel — it is suited to vertical runs between openings, column casings, narrow returns and ceiling linings where a light section is an advantage.
Two parameters should be checked before it is specified in a regulated space. First, the fire classification must be confirmed against the tested product scope for the specific SKU and colour: LONGTE's B1(B) classification under GB 8624-2012 (report BITFR202507063) is issued for the PVC wall panel scope tested, so the correct document for a PS fluted SKU should be requested at quotation stage rather than assumed. Second, the 10 mm section is a decorative lining, not a structural or acoustic element — it does not replace LT-AC where sound control is the design intent.
LT-WG — WPC Fluted Wall Panel, 159 × 2900 mm, 12 mm
Model: LT-WG (WPC Fluted Wall Panel, customizable)
Panel size: 159 × 2900 mm
Thickness: 12 mm
Groove depth: 8 mm
Performance: B1 fire rating; waterproof construction
Compliance on file: Combustion Performance Test Report BITFR202507063, issued 2025-07-15 by BITFR (Henan) Company Limited (CNAS L14889), classifying Class B1(B) under GB 8624-2012, tested to GB/T 20284-2006 and GB/T 8626-2007; RoHS HN202410860 valid to 2029-12-04
LT-WG is the heavy-duty member of the fluted pair. At 12 mm thick with an 8 mm groove depth, it produces a deeper shadow line than a 10 mm profile, and the WPC construction is specified as waterproof — the reason it appears in wet-adjacent walls, high-traffic circulation areas and commercial interiors where a decorative panel has to survive cleaning cycles. The 159 mm width and 2900 mm length place it between LT-PS and LT-AC in module terms: narrower than the acoustic module, wider than the PS detail profile.
For fire-rated commercial work, LT-WG is the clearest of the three to document. Report BITFR202507063 is a combustion performance test report issued by BITFR (Henan) Company Limited, a CNAS-accredited laboratory (L14889), covering GB/T 20284-2006, GB/T 8626-2007 and GB 8624-2012 Class B1(B). It is issued for the PVC wall panel scope stated on the certificate, so the report should be matched to the exact SKU and finish being supplied.

What the Shared Documentation Covers — and What It Does Not
All three models sit inside a RoHS verification, HN202410860, issued 2024-12-05 by Ningbo Helmsman Quality Testing Services Co., Ltd (HQTS) and valid to 2029-12-04, covering Directive 2011/65/EU and amendment (EU) 2015/863, with a scope that lists PVC wall panel, WPC wall panel, SPC wall panel, fluted wall panel, PVC marble sheet, UV marble sheet, bamboo charcoal wood veneer wall panel, carbon crystal wall panel, WPC decking and SPC flooring.
What the file does not do is certify every SKU for every application. Fire class, colour fastness, absorption and waterproof performance are product-specific. The specification task is therefore to match a named report to a named SKU, not to a product family.
Selection Matrix: LT-AC vs LT-PS vs LT-WG
| Parameter | LT-AC | LT-PS | LT-WG |
|---|---|---|---|
| Product name | Acoustic Slat Wood Wall Panel | PS Polystyrene Fluted Wall Panel | WPC Fluted Wall Panel |
| Panel size | 600 × 2400 mm | 150 × 2900 mm | 159 × 2900 mm |
| Thickness | 21 mm | 10 mm | 12 mm |
| Construction | MDF slats on polyester acoustic felt | PS core with UV surface film | WPC profile with 8 mm groove depth |
| Flute / groove geometry | Slat array on felt backing | 5 flutes across the face | 8 mm groove depth |
| Fire documentation | CE attestation TD15322304 (EN 13950:2014, EN 14496:2005), valid to 2028-12-17 | Confirm B1(B) report scope per SKU; RoHS HN202410860 applies | Class B1(B) per GB 8624-2012, report BITFR202507063; RoHS HN202410860 applies |
| Moisture exposure | Dry interior assemblies only — MDF slat core | Dry interior decorative lining | Waterproof construction |
| Typical application | Interior feature walls, hotel lobbies, meeting rooms, residential accent walls | Slim wall runs, column casings, ceiling linings, tight modules | High-traffic commercial walls, wet-adjacent areas, retail and office interiors |
| Customization | All three are available under OEM, ODM, private label and custom design, with customization of size, thickness, colour, surface pattern, logo printing, packaging, accessory kit and installation manual language | ||
Step-by-Step Specification Breakdown
- Fix the performance requirement before the finish. Write down, in order, the fire class the authority requires, the moisture exposure of the wall or ceiling, the substrate available, and whether sound control is a stated design intent. Only then open the panel catalogue. If sound control is stated, LT-AC is the only one of the three designed for that role; if the wall is wet-adjacent, LT-WG is the only one specified as waterproof.
- Match the fire document to the SKU. For LT-WG, request report BITFR202507063 and verify that the product scope and finish on the report correspond to the order. For LT-PS, request the combustion documentation for that specific fluted SKU. Confirm the RoHS verification HN202410860 as the shared environmental compliance document.
- Check the substrate against the assembly thickness. A 21 mm felt-backed slat panel requires a fixing design and batten layout appropriate to the added depth and weight; a 10 mm or 12 mm fluted profile changes the wall build-up and the finished plane. Confirm the available cavity, the door and window reveal depths, and the fixing method before the layout is frozen.
- Run the module arithmetic. Divide each elevation by 600 mm, 150 mm and 159 mm respectively, then compare cut waste at corners, openings and ceiling perimeters. On small rooms and heavily serviced walls, the narrower modules usually lose less material; on large uninterrupted planes, the 600 mm acoustic module reduces the number of joints.
- Define the ceiling condition separately. Ceiling specification is not a copy of the wall specification. The long 2900 mm lengths and light 10 mm section of LT-PS are the reason it is often considered for ceiling linings, while the acoustic assembly is normally reserved for walls where the felt backing can be installed against a controlled cavity.
- Lock the customization variables. Size, thickness, colour, surface pattern, logo printing, packaging, accessory kit and installation manual language are all customizable. Every variable changed at this stage affects the production route: standard stock runs 7–15 days, custom orders 25–40 days and large projects 45–60 days.
- Agree acceptance criteria before the first container. Pre-shipment inspection by SGS, BV or TUV is available on buyer request with cost shared; photo and video inspection is provided free of charge; samples are retained for six months for reference; and certificates of origin (CO, FORM E, FORM F) are issued with the shipment.
Use Cases: Interior Feature Walls, Ceilings and Commercial Spaces
Hotel lobbies and executive floors. A UAE villa developer and luxury fit-out company ordered 6,000 m² of PU stone panel and 4,000 m² of acoustic panel for a villa community and a five-star hotel, using the acoustic panels on lobby and executive suite walls. The project passed the Dubai Civil Defense fire test, and the developer subsequently signed a three-year exclusive frame agreement. The specification logic is repeatable: acoustic panel where sound control and a deep slat face are required, with fire documentation agreed before installation.
Residential bedroom and living room accent walls. The 600 × 2400 mm module of LT-AC covers a typical accent wall with few vertical joints, while LT-PS at 150 mm suits narrow returns, wardrobe surrounds and TV background framing where a fine flute pitch is the intent. In a residential context the deciding factor is usually module fit and substrate, not compliance.
Commercial office and retail interiors. LT-WG at 12 mm with an 8 mm groove depth and waterproof construction is the natural choice for corridors, reception walls, food-adjacent areas and other high-traffic surfaces that will be cleaned regularly. The deeper groove also holds a stronger shadow line under directional downlighting.
Ceilings. Where a fluted ceiling is specified, the 150 × 2900 mm, 10 mm LT-PS profile gives long continuous runs with minimal end joints; the fixing pattern and any required fire documentation for the ceiling assembly should be confirmed with the ceiling contractor.
Questions to Ask a Supplier About Substrate, Installation and Acceptance
- Substrate: Which substrate and batten spacing does the supplier recommend for a 21 mm felt-backed slat panel on a plasterboard partition, and for a 12 mm WPC profile on masonry?
- Installation: Is an installation video guide or a language-specific installation manual available, and is the accessory kit included in the shipment?
- Fire: Can the supplier issue the fire report for the exact SKU and colour being quoted, not only for the product family?
- Quality control: What in-process checks apply? LONGTE's stated regime is 100% incoming raw material inspection, in-process quality control every two hours, 100% finished goods visual and dimensional check, and third-party pre-shipment inspection on request.
- Acceptance: Are photo and video inspection, sample retention and certificates of origin included as standard, and who bears the cost of a third-party inspection?
- After-sales: What response time and warranty apply? LONGTE states free technical consultation, 24-hour WhatsApp response, installation video guides, claim handling within 7 days and a 5-year quality warranty on major products.
FAQ
What fire and compliance documents should a specifier request for fluted and acoustic wall panels?
Request the document that matches the exact SKU. For the WPC fluted line, LONGTE holds Combustion Performance Test Report BITFR202507063, issued 15 July 2025 by BITFR (Henan) Company Limited (CNAS L14889), classifying Class B1(B) under GB 8624-2012 and tested to GB/T 20284-2006 and GB/T 8626-2007; it is issued for the PVC wall panel scope stated on the report, so the SKU and finish must be verified against that scope. For the acoustic line, CE Attestation of Conformity TD15322304 covers Acoustic Panel under EN 13950:2014 and EN 14496:2005, issued by EUTEST Belgelendirme (Turkey) and valid to 2028-12-17. All lines sit inside RoHS Verification of Conformity HN202410860 under Directive 2011/65/EU and amendment (EU) 2015/863, valid to 2029-12-04.
Can fluted wall panels be supplied in custom lengths and finishes for OEM programmes?
Yes. LONGTE provides OEM, ODM, private label and custom design production services, and the customization scope covers size, thickness, colour, surface pattern, logo printing, packaging, accessory kit and installation manual language. Custom size and thickness are quoted per order, with a minimum of 500 m² per SKU for custom design. The standard catalogue dimensions remain 159 × 2900 mm for LT-WG and 150 × 2900 mm for LT-PS; any length change should be confirmed in writing at quotation stage because it alters the production route and lead time.
What are the minimum order quantities and payment terms?
Samples are supplied free — one to three pieces, with the buyer paying courier cost — and a trial order can be a 1×20GP mixed container of roughly 500–800 m². Custom design requires 500 m² per SKU, and a standard reorder is 1×40HQ per SKU. Default payment is 30% T/T deposit with 70% before shipment; L/C at sight applies to orders above USD 50,000; OA 30 days is available for long-term partners with credit insurance (Sinosure); Alibaba Trade Assurance is supported; and PayPal is accepted for sample fees under USD 500.
How should a sample be validated before a full order is placed?
Use the sample to confirm four things: that the module size and thickness match the drawing (600 × 2400 mm at 21 mm for LT-AC, 150 × 2900 mm at 10 mm for LT-PS, 159 × 2900 mm at 12 mm for LT-WG); that the surface film and groove depth match the approved reference; that the installation manual and accessory kit suit the site; and that the fire or environmental document issued with the sample corresponds to that SKU. LONGTE retains samples for six months for reference, provides free photo and video inspection, and accepts third-party pre-shipment inspection by SGS, BV or TUV on buyer request with cost shared.
What lead times apply to stock, custom and project orders?
Standard stock items run 7–15 days, custom orders 25–40 days, and large projects 45–60 days. Delivery is FOB Ningbo or Shanghai by default, with CIF to destinations including Los Angeles, New York, Dubai, Jebel Ali, Manila, Callao and Santos, and DDP door-to-door available for the USA, UAE, Colombia and Chile. To confirm which of the three models fits your elevation, request a sample and a technical quotation from the LONGTE team at halong105@hnhalong.com or WhatsApp +86 17757302351.
Conclusion
The three panels answer three different questions. LT-AC answers 'how do we control sound on a feature wall' — 600 × 2400 mm, 21 mm, MDF slats on polyester acoustic felt, with CE attestation TD15322304 behind it. LT-PS answers 'how do we get fine fluting into a narrow or long module' — 150 × 2900 mm, 10 mm, PS core with UV surface film and five flutes. LT-WG answers 'how do we get a deep fluted profile that survives a wet-adjacent, high-traffic commercial wall' — 159 × 2900 mm, 12 mm, 8 mm groove depth, B1 fire rating and waterproof construction, with report BITFR202507063 on file.
Specify in that order: performance requirement, documentation scope, substrate, module arithmetic, and only then finish. That sequence prevents the most expensive error in this category — a compliant-looking panel that cannot be installed on the wall it was drawn for.
Next step: compare the three profiles against your own elevation. LONGTE supplies free samples, technical quotations and the full product catalogue, and provides OEM, ODM and private-label production for distributors and project buyers.
Catalogue download: LONGTE Wall Panel & Flooring Catalogue (PDF)
Website: www.ltpvcfactory.com · Email: halong105@hnhalong.com · WhatsApp: +86 17757302351
Address: NO.10-1 Lianhong Road, Yuanhua Town, Haining City, Zhejiang Province, China

Have Questions or Need More Details?
Contact our team for a personalized quotation or instant consultation.
Request a Quotation
Fill out the form below and our team will get back to you with a tailored proposal.
WhatsApp Direct Chat
Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.
- Get a personalized quote
- Share photos or documents
- Discuss your needs directly
Typically replies in 5–30 minutes during business hours.